NOTICE: Website demonstration notice: Fictional Prairie region commercial roofing demonstration. All scope matrices, CAD planning figures, and schedules are illustrative samples.
SPEC: v2.4-MBWinnipeg & Prairie Central
Summit Commercial RoofingCAD / SCOPE

Procurement & Technical Scope Workbench • Winnipeg Hub

PROCUREMENT ESTIMATOR v2.4 NBC Climate Zone 7A • Manitoba Provincial Code Compliant CAD LINE ITEM INDEX

Commercial Low-Slope Budgeting Scopes & Procurement Rates

Transparent, defensible CAD unit cost envelopes and conditional membrane evaluation metrics for Winnipeg, Brandon, and Prairie facility capital planning.

Regional Baseline $14.20 – $24.50 CAD / sq. ft. Net
Target Thermal R-35 LTTR NECB Tier Compliant

Estimator Compliance Notice: All figures presented are engineered illustrative demonstration estimates calibrated for Prairie logistics hubs. No binding tender quote is executed prior to an intrusive core sampling test and dew-point dew-line physical audit.

ASSEMBLY SPEC: MB-2025-PR
STAGE 01 — ENVELOPE PARAMETERS

Parametric Scope Configurator

35,000 sq. ft.
10,000 sq ft (Light Commercial) 60,000 sq ft 120,000+ sq ft (Major Distribution Hub)
ENGINEERED BUDGET RANGE CAD ESTIMATE
$16.80 — $21.40 / sq. ft.

Total Capital Reserve: $588,000 – $749,000 CAD

Design Life 25 – 30 Years Annual preventative audit
Wind Uplift Rating FM 1-90 / CSA A123 Prairie gust verified
Recommended Prairie System:
2-Ply SBS Modified Bitumen (Cap Sheet + Base Sheet) with Staggered Polyiso R-35 LTTR & DensDeck Coverboard.

Formula Transparency Panel

CAD / SQ FT
Tear-off & Surface Prep $2.85 CAD
Polyiso R-35 LTTR (Dual Staggered) $4.95 CAD
Primary Waterproofing Membrane + Fasteners $8.20 CAD
Parapet Flashing & Drain Hub Surcharges $1.80 CAD
Zero-Fume / Occupancy Acoustic Protocol $0.00 CAD
Total Median Computed Rate $17.80 CAD / sq ft

*Includes Manitoba standard safety compliance (COR™), waste disposal, hoisting crane allowances, and RCABC/CRCA standard warranty administration fees.

WINNIPEG LOGISTICS PARK

Precision Core Sampling & Thermal Imaging Verification

Tested for -42°C cold-flex resilience and wind shears up to 110 km/h.

FACILITY ASSET MANAGEMENT MEMO

Prairie Capital Reserve Guidance: Separating Envelopes from MEP

Unlike interior mechanical or electrical equipment that experiences gradual component degradation, Prairie commercial roofing systems undergo extreme volumetric thermal cycling (+38°C to -40°C in an 8-month period). Inadequate capital reserves for building envelope renewal create compound liability:

Frost-Drive Dew Point Migration

Failure to spec dual-plane air/vapor retarders allows moisture from conditioned warehouse interiors to freeze inside the insulation core, reducing R-value by up to 60%.

Life-Cycle Depreciation Realities

Amortizing a 2-ply SBS system across a 25-year lifespan yields a replacement reserve need of roughly $0.65 to $0.85 CAD per square foot annually.

Aligned with ASTM D5147 tensile specifications & CRCA standard recommendations.
STAGE 02 — SPECIFICATION CRITERIA

Membrane System Conditional Decision Matrix

There is no single "best" commercial roofing material. Selection requires balancing thermal movement, foot traffic, chemical exposure, and installation season across Manitoba conditions.

Evaluation Criteria
TPO (60–80 mil)
Thermoplastic Polyolefin
EPDM Rubber (60–90 mil)
Thermoset Vulcanized Rubber
2-Ply SBS Mod-Bit
Elastomeric Bitumen + Granule
Prairie Sub-Zero Flexibility (-35°C to -45°C snap frost) FAIR / CONDITIONAL

Can stiffen significantly under -30°C. Requires specialized low-temp welding formulation.

EXCELLENT

Retains natural elastomeric flex down to -45°C. Superb recovery from freeze-thaw deflection.

OPTIMAL PRAIRIE SPEC

Elastomeric SBS polymers provide redundant cold-crack bridge capacity across fluted deck joints.

Ponding Water & Ice Damming Spring thaw drain blockages EXCELLENT

Heat-welded monolithic seams resist continuous standing water without seam degradation.

GOOD (WITH FACTORY TAPE)

Adhesive seam tapes perform well; requires strict prep to prevent moisture undercutting.

VERY HIGH

Dual layer redundant waterproof barrier prevents capillary leaks through thermal ice heave zones.

Mechanical Puncture Resistance Frequent HVAC servicing & debris MODERATE

Puncture vulnerability if unballasted. Recommends walkway pads around all RTU service routes.

MODERATE

Susceptible to sharp tools and windborne metal flashing cuts unless heavy 90-mil fleeceback is used.

SUPERIOR

Heavy granule surface plus two reinforcement mats (polyester + glass fiber) withstand intense maintenance foot traffic.

Winter Installation Window Field assembly below -10°C LIMITED (> -5°C)

Hot-air automatic welders require strict tenting and heat retention to assure seam shear strength.

RESTRICTED

Solvent-based primers and adhesives cannot cure below freezing temperatures without heaters.

EXCELLENT (TORCH-APPLIED)

Open-flame heat welded base and cap sheets allow successful installation even in deep Prairie winter conditions.

CapEx vs. Lifecycle OpEx Initial capital vs. 30-yr total cost LOWEST CAPEX

Most economical initial installation. Typical replacement cycle: 15–20 years.

BALANCED CAPEX

Moderate upfront cost with low ongoing repair expenses if properly inspected. 20–25 year life.

HIGHER INITIAL / LOWEST OPEX

Higher labor and material investment initially; lowest lifecycle cost over 25–30+ years.

Chemical & Grease Tolerance Exhaust vents, food manufacturing EXCELLENT

High resistance to animal fats, greases, and restaurant exhaust residues.

VULNERABLE

Petroleum and animal fats cause rubber swelling, softening, and premature membrane failure.

MODERATE

Requires grease collection containment traps around food-grade kitchen vents.

NECB 2020 / MB ENERGY CODE

Continuous Staggered R-35 LTTR

Single-layer polyiso allows 14% thermal bridging through fastener gaps. Summit specs require minimum dual-layer offset staggering (e.g., two 2.8" layers) with glued joints to guarantee true R-35 effective envelope value.

Code Compliant for Winnipeg Zone 7A
CSA A123.21 DYNAMIC TESTING

Edge Parapet Uplift Arrays

Prairie winter winds create violent negative pressure vortexes along parapets and corners. We deploy enhanced 6-inch fastening spacing in Zones 2 and 3 to ensure structural retention through 115 km/h gusts.

Factory Mutual 1-90 Compliant
3-TIER SITE QUALITY AUDIT

Non-Destructive Moisture Scans

Every completed square is verified with infrared thermography and high-frequency impedance probes prior to issuing our 20-Year No-Dollar-Limit (NDL) warranty document pack.

CRCA / SOPREMA / IKO Certified
NEXT STEP: PROCUREMENT ONBOARDING

Need a Defensible RFP Specification for Your Board?

Submit your building coordinates, historical roof leak reports, and CAD drawings. Our estimating engineers will draft a complete line-item CSI MasterFormat Section 07 52 00 tender packet within 48 hours.