Pureflow Air Prairie IAQ Architecture
STATION WPG-INTL | OAT: -24.6°C (EXTREME LOW) | SENSIBLE RECOVERY EFF: 78.4% SRE
ASHRAE 62.2 / NBCC SECTION 9.32
Manitoba Climatic Air Movement Series · Issue 04

The Air Movement Atlas for Prairie Buildings.

Clear, measurement-grounded ventilation, filtration, and psychrometric airflow planning for Winnipeg residences and commercial envelopes navigating extreme sub-zero differentials.

Static Limit 0.48 in. w.g. ESP
Core Balance ±4% CFM Sup / Exh
Winter RH 32% Envelope Safe
Psychrometric Profile
ATLAS-FIG. 01.A
WPG ZONE SAFE FROST RISK
CORE CONDENSATION THRESHOLD -12.8°C DEWPOINT

In prairie building science, ventilation is governed by the indoor glass condensation line. Balancing outdoor air delivery prevents attic frost drive while sustaining continuous CO₂ clearing.

Precision Over Panaceas

We do not sell miracle filter cartridges or proprietary ozone gadgets. Pureflow models static fan load, CSA F326 CFM balancing, and MERV 13 differential pressure profiles.

Three Prairie Structural Profiles

Interactive Airflow Vector Schematics

Examine how severe temperature swings alter intake thermal pre-tempering, plenum distribution friction, and exhaust moisture safety.

REF #01 Two-Story Residential: HRV Core & Forced-Air Balancing
NBCC 9.32.3 / CSA F326
EXTERIOR HOOD (-30°C INTAKE) INTERLOCK: FORCED-AIR PLENUM STALE AIR ROOF FLUE (+21°C EXHAUST)
R-50 ATTIC / R-24 DOUBLE ENVELOPE LEVEL 2: BEDROOM SUITES BASEMENT MECHANICAL PLATFORM HRV COUNTERFLOW SENSIBLE 79% EFF DEFROST RECIRC ECM BLOWER CONSTANT CFM ESP: 0.42" W.G. COLD INTAKE (-30°C) EXHAUST (-8°C) TEMPERED (+14°C) BEDROOM RISER (45 CFM) MAIN FLOOR (65 CFM)
Supply Total 110 CFM CONT.
Exhaust Ratio 106 CFM (BALANCED)
Filtration Drop 0.18" W.G. @ MERV 13
Core Protection RECIRC DAMPER
CSA F326 reference methodology Pitot-tube traverse data & manometer register sheet included
Winter Hazard Mitigation

The Prairie Negative Pressure Trap

In severe cold (-25°C to -40°C), an unbalanced exhaust HRV pulls cold prairie air into concealed wall cavities, causing structural freeze-thaw decay. We commission manometer balance across low and high speeds.

Blower interlock: SYNCHRONIZED ECM
Intake duct wrap: R-8 FOIL WRAP
Core defrost: TIMED RECIRCULATING
RESIDENTIAL DELIVERABLE

Commissioning Deliverable Package

Full digital balance log, motor watt verification, register balancing sheet, and clean air turnover rates room-by-room.

Systematic Advisory Pillars

Five Focused IAQ Engineering Scopes

Independent diagnostic balance. Pureflow operates purely as an advisory and commissioning consultancy—we do not sell equipment mark-ups or proprietary hardware.

STANDARDS: CSA F326 · ASHRAE 62.2 · HRAI COMPLIANT
SCOPE // 01

Ventilation Review

Full measurement of continuous fresh air baseline CFM. Verification of HRV/ERV sensible recovery core health, frost cycle duration, and intake louver clearance from snowdrifts.

Key Checkpoint: Intake/exhaust balance delta (<5 CFM target)
SCOPE // 02

Filtration Strategy

Evaluating particulate efficiency against fan static limitations. Designing MERV 11 to 14 transitions that filter wildfire smoke and prairie dust without choking blower motors.

Key Checkpoint: Filter rack static drop vs manufacturer fan curve
SCOPE // 03

Airflow Analysis

Pitot tube and anemometer duct traverses. Pinpoint why second-storey bedrooms or remote offices starve for air while primary floor supply grilles roar with excessive noise.

Key Checkpoint: Trunk velocity profiles & damper balancing
SCOPE // 04

Seasonal Protocols

Customized seasonal playbooks. Calibrating winter low-humidity targets (protecting attic sheathing) versus summer latent cooling dehumidification profiles across June–August.

Key Checkpoint: Winter window condensation prevention table
SCOPE // 05

Contractor Liaison

Clear, unyielding mechanical specs for your sheet metal installer or HVAC contractor. We speak their technical dialect, provide target CFM numbers, and verify work post-install.

Key Checkpoint: Independent third-party verification report
Transparent Scope Basics

Demonstrative Planning Ranges

Clear mechanical review envelopes for Winnipeg and Red River Basin properties. Each scope reflects field instrument hours, engineering analysis, and formal report generation.

View Comprehensive Fee Schedule
SCOPE LEVEL I RESIDENTIAL BASIC

Residential IAQ & HRV Diagnostic

Single-dwelling assessment focused on core balancing, furnace blower external static pressure measurement, and intake screen verification.

Field Time: 2.5–3.5 Hours On-Site
Instrumentation: Digital Manometer & Hood
Baseline Planning: $550 – $750 CAD
  • Supply & exhaust airflow CFM balance
  • Total static duct resistance check
  • Winter indoor RH safe-limit calibration
SCOPE LEVEL II Most Requested Scope

Comprehensive Distribution & Duct Audit

For homes or offices with uneven temperatures, persistent dust, noisy registers, or post-addition airflow issues.

Field Time: 4.5–6.0 Hours On-Site
Instrumentation: Flow Grid, CO₂ Logger, Pitot
Baseline Planning: $1,100 – $1,650 CAD
  • Individual register flow hood quantification
  • MERV 13 pressure drop upgrade simulation
  • Attic bypass and envelope duct leakage check
  • Contractor-ready duct alteration layout
SCOPE LEVEL III COMMERCIAL SUITE

Commercial Suite / DOAS Commissioning

Designed for professional offices, clinics, and multi-tenant suites needing verified compliance under ASHRAE 62.1 standards.

Field Time: Full Day Field + Studio Analysis
Instrumentation: Multi-Gas + Velocity Hoods
Baseline Planning: $2,200 – $3,800 CAD
  • ASHRAE outdoor air rate compliance report
  • CO₂ peak logging in high-density boardrooms
  • Exhaust-to-supply envelope pressure balance
Physical Commissioning Environments

Instrument reference on the Coldest Mornings.

You cannot balance a prairie ventilation system from a computer simulation alone. When the outside air drops below -30°C, air density increases, dampers stiffen, and thermal stack effect alters circulation paths.

True In-Duct Static Pressure:

Determining whether high-efficiency MERV 13 filtration is inadvertently starving the blower motor or tripping high-limit thermal switches.

Envelope Psychrometric Limits:

Establishing exact relative humidity safety ceilings to keep your window sills and wall assemblies bone dry while maintaining comfort.

Balanced mechanical ventilation HRV core installed inside a modern residential mechanical room in Winnipeg
HRV COUNTERFLOW CORE COMMISSIONING
Air quality technician using a digital flow hood and manometer to measure CFM volume from a commercial ceiling diffuser
TERMINAL REGISTER VELOCITY TESTING

Honest Prairie Engineering Disclaimer & Boundaries

NO MEDICAL CLAIMS

Pureflow Air is an architectural mechanical consulting and airflow commissioning service. We do not manufacture medical devices, promise allergy treatment, or endorse unscientific ionization hardware. Air quality improvements result strictly from calculated fluid dynamics: adequate outdoor air replacement (ACH), balanced mechanical ventilation, envelope moisture management, and verified particulate filtration efficiency under CSA F326 and ASHRAE guidelines.

• FACTUAL FLOW BALANCING • INDEPENDENT OF HVAC HARDWARE SALES • Manitoba consulting framework to confirm
Initiate An Advisory Review

Ready for a Measurable Evaluation of Your Building's Air Movement?

Share your floor plan, mechanical equipment schedule, or cold-weather symptoms. We’ll outline a straightforward diagnostic plan.

Winnipeg, MB & Surrounding Rural Municipalities · Typical response within 1 business day