WEBSITE DEMONSTRATION·Illustrative prairie indoor air planning consultancy
Lat 49.8954° N · Winnipeg, MB
PUREFLOW AIRMB-7A
PRAIRIE IAQ ARCHITECTURE
DOCUMENT REF: MB-ENG-2025-V4 FIVE reference CONSULTING PILLARS // CAN/CSA F326 & ASHRAE 62.2 COMPLIANT
ZONE 7A SUB-ZERO RESILIENT INSPECTION ATLAS
PRAIRIE CLIMATIC SPECIALIZATION YWG // 49.8954° N

Ventilation, Filtration & Airflow Engineering Services

Independent advisory engineering for prairie building envelopes navigating sub-zero temperature gradients, seasonal wildfire plume infiltration, and positive-pressure envelope dynamics. Pureflow Air acts solely as an unbiased consulting authority—we do not sell mechanical equipment or claim universal remediation.

Bespoke Psychrometric Models
Multi-Point Pitot Logging
Zero Equipment Commission Sales
ATMOSPHERIC TELEMETRY MET-STATION 01
EXTREME PEAK -38.2°C Design Low Base
TARGET ENVELOPE ±4 CFM Static Neutrality
RH DEPRESSION 28-32% Sub-Zero Cap
WILDFIRE SMOKE MERV 13 Dynamic Stage-Up
All consultation parameters align directly to Manitoba Building Code 9.32.
MODULE 01 Counterflow Core Verification Sensible Recovery Latency Testing
MODULE 03 Static Pressure Diagnostics Pitot Traverses across 12 Duct Runs
MODULE 04 Sub-Zero Psychrometrics Triple-Glaze Condensation Modeling
CORE TECHNICAL PILLARS

Systematic Envelope & Mechanical Advisory

Each scope provides thorough, non-commercial documentation designed to interface directly with mechanical engineers, general contractors, and jurisdictional authorities.

01

Ventilation Review & Core Balancing

HRV / ERV SENSIBLE RECOVERY & DEFROST STAGING
TARGET: NEUTRALITY (±4 CFM)

Prairie winter conditions present destructive thermal tensions across balanced ventilation cores. When outdoor temperatures drop past -25°C, moisture freezing inside the exhaust matrix requires precise frost-control dampers or recirculation cycles. We quantify real-time sensible heat recovery efficiency, establish neutral building static equilibrium to prevent moisture-laden air from penetrating exterior envelope framing, and audit intake hoods against blizzard snowdrifts.

Core Recovery: 68% to 81% Verified
Intake Clearance: 450mm Above Grade Snowline
Defrost Threshold: Recirculate at -12°C Ambient
Target Static: CAN/CSA F326 ±4 CFM
INCLUDES ON-SITE MAGNEHELIC PRESSURE DIFFERENTIAL AUDIT
FIG 1.1: COUNTERFLOW CORE AIR DYNAMICS SCALE: N.T.S.
ALUMINUM CORE FRESH AIR IN (-30°C) SUPPLY TEMPERED (+14°C) WARM RETURN (+21°C) EXHAUST STALE (-12°C) DAMPER 5G
SENSIBLE EFFICIENCY: 74.2% CORE RESISTANCE: 0.28 IN. W.G.
02

Filtration Strategy & Particle Resistance

MERV 11 TO 14 EVALUATION VS HEPA BLOWER STATIC LIMITS
PRAIRIE SMOKE SHIELD

Elevating residential or light commercial filtration to counter summer wildfire smoke plumes frequently suffocates standard ECM air handlers. Installing deep HEPA cartridges without duct modification creates excessive static backpressure, stalling heat exchangers and burning out fan motors. We audit your blower fan curve against clean vs loaded filter resistance to identify the exact filter media thickness, face velocity, and bypass damper architecture suitable for seasonal switching.

Standard 1-inch MERV 8 Baseline typical furnace installation
ΔP: 0.12 in. w.g. LOW CAPTURE
Engineered 4-inch Deep MERV 13 Pureflow Prairie Wildfire Recommended Standard
ΔP: 0.22 in. w.g. OPTIMAL EQUILIBRIUM
Direct-Plenum True HEPA 99.97% High risk of static stall without booster
ΔP: 0.85 in. w.g. FAN OVERLOAD DANGER
FIG 2.1: FAN STATIC CAPACITY VS MEDIA TYPE CFM: 1200 FLOW
MERV 8 (1-inch) 0.14 in. w.g.
MERV 13 (4-inch Pleat) 0.24 in. w.g.
MERV 16 (High Resistance) 0.48 in. w.g.
In-line Direct HEPA (Un-boosted) 0.88 in. w.g. [OVER CRITICAL]
Recommended envelope limit for standard variable-speed ECM blower: 0.50 in. w.g. total external static pressure (TESP).
03

Airflow Context & Ductwork Static Analysis

PITOT-TUBE TRAVERSE LOGGING & DAMPER BALANCING
ACOUSTIC & VELOCITY COMFORT

Thermal starvation on second storeys and disruptive register turbulence are rarely resolved by simply turning up the blower speed—in fact, doing so exacerbates duct hiss and accelerates envelope duct leakage. We perform rigorous multi-traverse duct velocity calculations using precision differential pressure probes, diagnosing bottleneck elbows, unsealed flex-duct transitions, and pinched return airways.

REGISTER ROAR > 700 FPM

Eliminates audible register whistle through damper adjustment.

SECOND FLOOR STARVE ΔT > 4.5°C

Re-indexes supply trunk split fractions to equalize vertical thermal stacks.

DUCT TIGHTNESS < 3 CFM / 100 SQFT

Prevents pressurized unconditioned plenum leakage.

FIG 3.1: TRAVERSE PRESSURE TRANSDUCER ACCURACY: ±0.5%
TRAVERSE POINT A1 (SUPPLY MAIN) 840 FPM / 0.42 IN.
TRAVERSE POINT A2 (SUPPLY CORE) 910 FPM / 0.44 IN.
BRANCH B3 (UPPER FLR NORTH) 310 FPM [DEFICIT]
BRANCH B4 (LIVING RM BOOT) 780 FPM [TURBULENT]
DAMPER MATRIX BALANCING PROFILE COMPILED IN FIELD
04

Seasonal Protocols & Psychrometric Defrost Management

DEEP WINTER RH DEPRESSION & SUMMER DEW POINT DECOUPLING
ENVELOPE MOISTURE SAFETY

When extreme continental cold pushes outdoor moisture capacity below 1.0 g/kg of dry air, unreference continuous mechanical ventilation rapidly depresses indoor relative humidity below 18%, provoking respiratory discomfort and wood finish shrinkage. Conversely, excessive humidification drives interstitial condensation at window framing corners and unsealed attic penetrations. We map safe psychrometric boundaries reference against window U-values and outdoor temperatures.

WINNIPEG WINTER RELATIVE HUMIDITY TARGETING MODEL
OUTDOOR TEMP -10°C Target RH: 35%
OUTDOOR TEMP -20°C Target RH: 30%
OUTDOOR TEMP -30°C Target RH: 20-25%
FIG 4.1: CONDENSATION PROFILE MATRIX DOUBLE VS TRIPLE PANE
Dew Point Boundary

At -30°C outdoor ambient, standard double-glazed windows experience edge perimeter condensation if indoor humidity exceeds 22%. Triple-glazed assemblies (Low-E argon) allow up to 32% indoor RH before edge frosting. Our advisory models prevent structural rot behind vapor barriers.

VAPOR BARRIER PRESSURIZATION: SLIGHT NEGATIVE PREVENTATIVE
05

Maintenance & Equipment Coordination

INDEPENDENT COMMISSIONING & MECHANICAL SCHEDULE LIAISON
THIRD-PARTY VALIDATION

We bridge the gap between architectural plans and physical mechanical installations. Because Pureflow Air does not sell equipment or execute sheet metal fabrication, trades welcome our technical verification as clear, third-party sign-off. We verify mechanical schedules, conduct pre-occupancy airflow balances, and issue illustrative engineering compliance records for occupancy permits.

Pre-Pour & Rough-In Check Auditing trunk dimensions prior to drywall encapsulation.
Defrost Cycle Verification Confirming 5th wire defrost damper actuation at temperature.
Airflow Balancing Report Stamped documentation verifying CAN/CSA F326 target delivery.
Occupant Season Runbook Custom bi-annual filter and core maintenance schedule.
COMMISSIONING DELIVERABLE SPECIMEN DOC MB-F326-CERT
AIR BALANCING RECORD
PROJECT:SOUTH CHARLES RESIDENCE
TOTAL DESIGN CFM:165 CFM
MEASURED SUPPLY:163 CFM
MEASURED EXHAUST:166 CFM
NET STATIC VARIANCE:-3 CFM (PASS)
INSPECTOR ID:MB-PE-8841
RECOGNIZED BY JURISDICTIONAL SAFETY INSPECTORS
PROJECT TYPOLOGY MATRIX

Compare Engineering Scopes & Deliverables

Filter advisory deliverables based on building archetype, occupancy density, and envelope age across the Manitoba region.

RESIDENTIAL SINGLE-FAMILY SCOPE RSF-01

Comprehensive Envelope IAQ Audit

Designed for new high-performance prairie residential builds (R-40+ roofs, triple-pane glass) or major retrofits encountering mysterious window condensation, register roar, or uneven room temperatures.

TYPICAL ONSITE DURATION 3.5 to 5 Hours Field Telemetry Followed by 5-day psychrometric reporting turnaround
INCLUDED DELIVERABLES & COMPLIANCE ARTIFACTS
Traverse CFM Airflow Log Per-room actual CFM vs designed standard load.
F326 Balancing Record Illustrative balance document for review records.
TESP Resistance Curve Static pressure breakdown for filter staging.
Winter RH Setpoint Guide Exact condensation thresholds for window warranties.
Standard Residential Scope Range: $850 – $1,400 CAD Request Specification Sheet →
TRANSPARENT ENGINEERING BOUNDARY

Unbiased Consulting Authority. No Hardware Sales.

We do not endorse unscientific ionization hardware, promise allergy treatment, or sell HVAC inventory. Our revenue stems exclusively from qualified engineering hours and calibration testing. If your existing duct network is adequate, we tell you immediately without upselling replacement equipment.

NON-COMMERCIAL CHARTER
Read Engineering Code
SCHEDULE AN AIR-QUALITY DISCOVERY AUDIT

Discuss an air-quality scope for your facility

Reach our Winnipeg engineering desk to request a diagnostic field traverse, mechanical schedule review, or CAN/CSA F326 ventilation balance Illustrative Record.

Winnipeg IAQ Lab: Portage & Main Concourse Direct: (204) 555-0192 dispatch@pureflowair.ca